Show Hamamatsu Avalanche Photo Diode 2410026716 - Archived data from Wed, 12. June 2019 16:46:31 CEST
This is all the information about APD 2410026716. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 2410026716 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | unknown |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | D14 |
Break-through voltage: | 415 V |
Voltage for Gain 100 (T=+25°C): | 387.2 V |
Dark current: | 6.9 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 15 |
Position in Box: | 20 |
EP1 batch: | 40 |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | 12. Nov 2018 |
Sent for analysis after irradiation: | 13. Dec 2018 |
Return for assembly: | none |
Irradiation: | |
Date: | 07. Dec 2018 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 10. Dec 2018 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
Break-through voltage: | T = +20 °C: none T = -25 °C: none |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 10:49:41 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:15:51 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:22:12 CEST | jreher | Updated APD characteristics via API. |
27. Nov 2019 19:32:04 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:12:04 CET | jreher | Updated box and position via API. |
25. Jul 2019 10:24:58 CEST | jreher | |
04. Jul 2019 11:08:14 CEST | jreher | Updated APD location via API. |
12. Jun 2019 16:46:31 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 16:31:26 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 15:03:45 CEST | jreher | Updated APD batch assignment via API. |
15. Feb 2019 14:13:32 CET | jreher | Updated APD batch assignment via API. |
15. Feb 2019 14:13:20 CET | jreher | Updated APD batch assignment via API. |
15. Feb 2019 14:12:23 CET | jreher | Updated APD batch assignment via API. |
15. Feb 2019 14:12:00 CET | jreher | Updated APD batch assignment via API. |
15. Feb 2019 13:58:07 CET | jreher | Updated APD batch assignment via API. |
15. Feb 2019 13:57:41 CET | jreher | Updated APD batch assignment via API. |
15. Feb 2019 13:54:37 CET | jreher | Updated APD batch assignment via API. |
15. Feb 2019 13:52:17 CET | jreher | Updated APD batch assignment via API. |
15. Feb 2019 13:51:47 CET | jreher | Updated APD batch assignment via API. |
15. Feb 2019 13:51:19 CET | jreher | Updated APD batch assignment via API. |
15. Feb 2019 13:48:38 CET | jreher | Updated APD batch assignment via API. |
03. Jan 2019 00:11:33 CET | Tobias | Corrected dark current unit. |
13. Dec 2018 11:49:51 CET | markus.moritz | |
23. Nov 2018 14:17:22 CET | markus.moritz | |
12. Jan 2018 13:11:42 CET | Tobias | Imported from Hamamatsu datasheet. |