RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2410026702 - Archived data from Wed, 03. February 2021 18:15:49 CET


This is all the information about APD 2410026702. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2410026702
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2410026702/0721006960
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: blue
   
Manufacturer information:  
Wafer position: F04
Break-through voltage: 408 V
Voltage for Gain 100 (T=+25°C): 379.7 V
Dark current: 4.4 nA
   
Screening Logistics:  
Available: No
Storage Box: 15
Position in Box: 7
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 12. Nov 2018
Sent for analysis after irradiation: 13. Dec 2018
Return for assembly: none
   
Irradiation:  
Date: 07. Dec 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 10. Dec 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 380.2646681 V     T = -25 °C: 344.9203149 V
Voltage for Gain 150: T = +20 °C: 388.0628658 V     T = -25 °C: 352.2566869 V
Voltage for Gain 200: T = +20 °C: 392.4425659 V     T = -25 °C: 356.4543949 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.548014441 V-1     T = -25 °C: 4.920357799 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.687583908 V-1     T = -25 °C: 9.590203742 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.08283096 V-1     T = -25 °C: 16.69507624 V-1
Break-through voltage: T = +20 °C: 408.0174671 V     T = -25 °C: 371.4205578 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:49:39 CET jreher Updated box and position via API.
03. Feb 2021 18:15:49 CET jreher Updated box and position via API.
11. Aug 2020 17:22:09 CEST jreher Updated APD characteristics via API.
31. Mar 2020 08:51:54 CEST jreher Assigned to capsule by script
13. Feb 2020 14:19:56 CET jreher Updated box and position via API.
27. Nov 2019 19:32:03 CET jreher Updated APD location via API.
25. Nov 2019 17:12:03 CET jreher Updated box and position via API.
04. Jul 2019 11:08:13 CEST jreher Updated APD location via API.
12. Jun 2019 16:46:30 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:31:25 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:03:44 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:11:33 CET Tobias Corrected dark current unit.
13. Dec 2018 11:58:24 CET markus.moritz
23. Nov 2018 14:20:02 CET markus.moritz
12. Jan 2018 13:11:42 CET Tobias Imported from Hamamatsu datasheet.