Show Hamamatsu Avalanche Photo Diode 0612004938 - Archived data from Wed, 07. October 2020 15:44:30 CEST
This is all the information about APD 0612004938. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 0612004938 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | In transit to Mainz |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | D01 |
Break-through voltage: | 439 V |
Voltage for Gain 100 (T=+25°C): | 412.3 V |
Dark current: | 11.2 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 265 |
Position in Box: | 29 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 638 |
Position in grid: | 14 |
Arrival for irradiation: | none |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 412.067979 V T = -25 °C: 374.6853572 V |
Voltage for Gain 150: | T = +20 °C: 420.0516747 V T = -25 °C: 382.5836828 V |
Voltage for Gain 200: | T = +20 °C: 424.4787396 V T = -25 °C: 386.9657056 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.471980823 V-1 T = -25 °C: 4.405187134 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.829817058 V-1 T = -25 °C: 9.066095667 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 15.50143415 V-1 T = -25 °C: 14.67908613 V-1 |
Break-through voltage: | T = +20 °C: 438.7416815 V T = -25 °C: 401.8493442 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:22:28 CET | jreher | Updated box and position via API. |
07. Oct 2020 15:44:30 CEST | jreher | Updated APD location via API. |
11. Aug 2020 17:49:44 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:35:15 CEST | jreher | Updated box and position via API. |
27. Nov 2019 20:15:29 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:30:43 CET | jreher | Updated box and position via API. |
25. Nov 2019 17:16:36 CET | spankonin | Updated APD batch assignment via API. |
27. Oct 2017 10:23:25 CEST | Tobias | Resetted arrival for irradiation date as APDs are returned to GSI un-irradiated. |
29. Sep 2017 09:51:59 CEST | markus.moritz | Entered arrival for irradiation date. |
21. Nov 2016 17:44:54 CET | Tobias | Assigned to grid via information extracted from APD DB. |
21. Nov 2016 17:24:47 CET | tobias | Manually added based on APD lab DB export. |