RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0611004885 - Archived data from Tue, 11. August 2020 17:49:46 CEST


This is all the information about APD 0611004885. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0611004885
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F04
Break-through voltage: 449 V
Voltage for Gain 100 (T=+25°C): 420.5 V
Dark current: 13.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 265
Position in Box: 36
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 638
Position in grid: 11
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 420.2951937 V     T = -25 °C: 383.4696816 V
Voltage for Gain 150: T = +20 °C: 428.1637047 V     T = -25 °C: 391.3292257 V
Voltage for Gain 200: T = +20 °C: 432.5221974 V     T = -25 °C: 395.6626517 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.479761521 V-1     T = -25 °C: 4.32625294 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.841987232 V-1     T = -25 °C: 8.687446071 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.55423675 V-1     T = -25 °C: 15.5731645 V-1
Break-through voltage: T = +20 °C: 439.9887157 V     T = -25 °C: 411.2992196 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:22:29 CET jreher Updated box and position via API.
07. Oct 2020 15:44:31 CEST jreher Updated APD location via API.
11. Aug 2020 17:49:46 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:35:15 CEST jreher Updated box and position via API.
27. Nov 2019 20:15:30 CET jreher Updated APD location via API.
25. Nov 2019 17:30:43 CET jreher Updated box and position via API.
25. Nov 2019 17:16:37 CET spankonin Updated APD batch assignment via API.
27. Oct 2017 10:23:25 CEST Tobias Resetted arrival for irradiation date as APDs are returned to GSI un-irradiated.
29. Sep 2017 09:51:59 CEST markus.moritz Entered arrival for irradiation date.
21. Nov 2016 17:44:54 CET Tobias Assigned to grid via information extracted from APD DB.
21. Nov 2016 17:23:20 CET tobias Manually added based on APD lab DB export.