Show Hamamatsu Avalanche Photo Diode 0612004928 - Archived data from Tue, 11. August 2020 17:49:43 CEST
This is all the information about APD 0612004928. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 0612004928 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | D03 |
Break-through voltage: | 443 V |
Voltage for Gain 100 (T=+25°C): | 414.3 V |
Dark current: | 11.8 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 265 |
Position in Box: | 23 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 638 |
Position in grid: | 2 |
Arrival for irradiation: | none |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 414.4384189 V T = -25 °C: 377.2730763 V |
Voltage for Gain 150: | T = +20 °C: 422.4046574 V T = -25 °C: 385.0894647 V |
Voltage for Gain 200: | T = +20 °C: 426.8000877 V T = -25 °C: 389.4759197 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.382014147 V-1 T = -25 °C: 4.606731436 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.485632856 V-1 T = -25 °C: 8.823875276 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.67064705 V-1 T = -25 °C: 15.29636439 V-1 |
Break-through voltage: | T = +20 °C: 439.9213281 V T = -25 °C: 405.3609533 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:22:27 CET | jreher | Updated box and position via API. |
07. Oct 2020 15:44:30 CEST | jreher | Updated APD location via API. |
11. Aug 2020 17:49:43 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:35:14 CEST | jreher | Updated box and position via API. |
27. Nov 2019 20:15:29 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:30:42 CET | jreher | Updated box and position via API. |
25. Nov 2019 17:16:35 CET | spankonin | Updated APD batch assignment via API. |
27. Oct 2017 10:23:25 CEST | Tobias | Resetted arrival for irradiation date as APDs are returned to GSI un-irradiated. |
29. Sep 2017 09:51:59 CEST | markus.moritz | Entered arrival for irradiation date. |
21. Nov 2016 17:44:54 CET | Tobias | Assigned to grid via information extracted from APD DB. |
21. Nov 2016 17:18:43 CET | tobias | Manually added based on APD lab DB export. |