Show Hamamatsu Avalanche Photo Diode 2319025801 - Archived data from Thu, 16. January 2020 11:57:36 CET
This is all the information about APD 2319025801. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 2319025801 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | D08 |
Break-through voltage: | 409 V |
Voltage for Gain 100 (T=+25°C): | 380.4 V |
Dark current: | 3.8 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 252 |
Position in Box: | 10 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | 21. Aug 2019 |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
Break-through voltage: | T = +20 °C: none T = -25 °C: none |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:20:43 CET | jreher | Updated box and position via API. |
07. Oct 2020 12:19:11 CEST | jreher | Assigned to capsule by script |
17. Aug 2020 15:54:06 CEST | jreher | Updated box and position via API. |
11. Aug 2020 17:42:42 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:32:53 CEST | jreher | Updated box and position via API. |
16. Jan 2020 12:06:09 CET | jreher | Updated date sent for analysis after screening via API. |
16. Jan 2020 12:04:19 CET | jreher | Updated annealing info via API. |
16. Jan 2020 12:01:29 CET | jreher | Updated irradiation info via API. |
16. Jan 2020 11:58:37 CET | jreher | Updated arrival for irradiation via API. |
16. Jan 2020 11:57:36 CET | jreher | Updated arrival for irradiation via API. |
27. Nov 2019 20:13:26 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:30:02 CET | jreher | Updated box and position via API. |
22. Oct 2019 16:34:05 CEST | spankonin | Updated APD batch assignment via API. |
22. Oct 2019 16:15:24 CEST | spankonin | Updated APD location via API. |
23. Jun 2016 12:00:18 CEST | Tobias | Imported from Hamamatsu datasheet. |