Show Hamamatsu Avalanche Photo Diode 2319025776 - Archived data from Fri, 05. February 2021 11:16:44 CET
This is all the information about APD 2319025776. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 2319025776 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | H09 |
Break-through voltage: | 414 V |
Voltage for Gain 100 (T=+25°C): | 387.5 V |
Dark current: | 3.9 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 220 |
Position in Box: | 38 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | 21. Aug 2019 |
Sent for analysis after irradiation: | 15. Oct 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 09. Oct 2019 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 12. Oct 2019 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 386.716493 V T = -25 °C: 350.7599276 V |
Voltage for Gain 150: | T = +20 °C: 394.5663121 V T = -25 °C: 358.2555005 V |
Voltage for Gain 200: | T = +20 °C: 398.8968641 V T = -25 °C: 362.4529632 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.702622406 V-1 T = -25 °C: 4.926075855 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.401503802 V-1 T = -25 °C: 9.075112128 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.77726896 V-1 T = -25 °C: 16.20496321 V-1 |
Break-through voltage: | T = +20 °C: 413.2582992 V T = -25 °C: 377.3416506 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
16. Nov 2021 10:39:42 CET | oafedulidis | Assigned to capsule by script |
21. Apr 2021 11:02:30 CEST | jreher | Updated box and position via API. |
05. Feb 2021 11:16:44 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:42:37 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:27:40 CEST | jreher | Updated box and position via API. |
16. Jan 2020 12:06:07 CET | jreher | Updated date sent for analysis after screening via API. |
16. Jan 2020 12:04:17 CET | jreher | Updated annealing info via API. |
16. Jan 2020 12:01:28 CET | jreher | Updated irradiation info via API. |
16. Jan 2020 11:58:35 CET | jreher | Updated arrival for irradiation via API. |
16. Jan 2020 11:57:34 CET | jreher | Updated arrival for irradiation via API. |
27. Nov 2019 20:07:57 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:28:04 CET | jreher | Updated box and position via API. |
22. Oct 2019 16:34:03 CEST | spankonin | Updated APD batch assignment via API. |
22. Oct 2019 16:12:05 CEST | spankonin | Updated APD location via API. |
23. Jun 2016 12:00:17 CEST | Tobias | Imported from Hamamatsu datasheet. |