Show Hamamatsu Avalanche Photo Diode 2319025749 - Archived data from Fri, 05. February 2021 11:16:41 CET
This is all the information about APD 2319025749. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 2319025749 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | B06 |
Break-through voltage: | 412 V |
Voltage for Gain 100 (T=+25°C): | 383 V |
Dark current: | 4.9 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 58 |
Position in Box: | 37 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | 21. Aug 2019 |
Sent for analysis after irradiation: | 15. Oct 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 09. Oct 2019 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 12. Oct 2019 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 382.907692 V T = -25 °C: 347.6374664 V |
Voltage for Gain 150: | T = +20 °C: 390.7323976 V T = -25 °C: 355.0473329 V |
Voltage for Gain 200: | T = +20 °C: 395.0677538 V T = -25 °C: 359.2049664 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.658245191 V-1 T = -25 °C: 4.676035095 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.314895152 V-1 T = -25 °C: 9.398815074 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.50571305 V-1 T = -25 °C: 14.88453696 V-1 |
Break-through voltage: | T = +20 °C: 408.7192165 V T = -25 °C: 374.6852771 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
25. Sep 2021 16:11:23 CEST | oafedulidis | Assigned to capsule by script |
10. May 2021 14:01:17 CEST | oafedulidis | Updated box and position via API. |
26. Apr 2021 14:30:14 CEST | oafedulidis | Updated box and position via API. |
05. Feb 2021 11:16:41 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:42:32 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:27:38 CEST | jreher | Updated box and position via API. |
16. Jan 2020 12:06:05 CET | jreher | Updated date sent for analysis after screening via API. |
16. Jan 2020 12:04:15 CET | jreher | Updated annealing info via API. |
16. Jan 2020 12:01:26 CET | jreher | Updated irradiation info via API. |
16. Jan 2020 11:58:33 CET | jreher | Updated arrival for irradiation via API. |
16. Jan 2020 11:57:32 CET | jreher | Updated arrival for irradiation via API. |
27. Nov 2019 20:07:55 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:28:02 CET | jreher | Updated box and position via API. |
22. Oct 2019 16:33:30 CEST | spankonin | Updated APD batch assignment via API. |
22. Oct 2019 16:32:08 CEST | spankonin | Updated APD location via API. |
23. Jun 2016 12:00:16 CEST | Tobias | Imported from Hamamatsu datasheet. |