Subdetector specification: | |
---|---|
Serial: | 2318025706 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | D08 |
Break-through voltage: | 412 V |
Voltage for Gain 100 (T=+25°C): | 383.4 V |
Dark current: | 8.2 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 230 |
Position in Box: | 45 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | 21. Aug 2019 |
Sent for analysis after irradiation: | 15. Oct 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 09. Oct 2019 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 12. Oct 2019 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 383.311629 V T = -25 °C: 347.6102362 V |
Voltage for Gain 150: | T = +20 °C: 391.1805159 V T = -25 °C: 355.0194283 V |
Voltage for Gain 200: | T = +20 °C: 395.5662693 V T = -25 °C: 359.1591135 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.506664068 V-1 T = -25 °C: 4.715204605 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.805174449 V-1 T = -25 °C: 9.480674513 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 15.3498096 V-1 T = -25 °C: 14.98488448 V-1 |
Break-through voltage: | T = +20 °C: 411.3555364 V T = -25 °C: 374.6124812 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:17:58 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:41:19 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:29:20 CEST | jreher | Updated box and position via API. |
16. Jan 2020 12:06:02 CET | jreher | Updated date sent for analysis after screening via API. |
16. Jan 2020 12:04:13 CET | jreher | Updated annealing info via API. |
16. Jan 2020 12:01:23 CET | jreher | Updated irradiation info via API. |
16. Jan 2020 11:58:31 CET | jreher | Updated arrival for irradiation via API. |
16. Jan 2020 11:57:30 CET | jreher | Updated arrival for irradiation via API. |
27. Nov 2019 20:09:45 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:28:46 CET | jreher | Updated box and position via API. |
22. Oct 2019 12:54:27 CEST | spankonin | Updated APD location via API. |
18. Oct 2019 14:03:25 CEST | jgrochowski | Updated APD batch assignment via API. |
23. Jun 2016 12:00:15 CEST | Tobias | Imported from Hamamatsu datasheet. |