Serial: 2318025688
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: H08
Break-through voltage: 416 V
Voltage for Gain 100 (T=+25°C): 388.1 V
Dark current: 8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 230
Position in Box: 30
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 21. Aug 2019
Sent for analysis after irradiation: 15. Oct 2019
Return for assembly: none
   
Irradiation:  
Date: 09. Oct 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 12. Oct 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 387.8826546 V     T = -25 °C: 351.9877473 V
Voltage for Gain 150: T = +20 °C: 395.7453061 V     T = -25 °C: 359.5202944 V
Voltage for Gain 200: T = +20 °C: 400.1085269 V     T = -25 °C: 363.729924 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.639783043 V-1     T = -25 °C: 4.813243762 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.163547115 V-1     T = -25 °C: 8.838386934 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.28309952 V-1     T = -25 °C: 15.44717766 V-1
Break-through voltage: T = +20 °C: 415.1021618 V     T = -25 °C: 378.9649698 V
   
Notes:


Version history

Time Author Change comment
16. Nov 2021 09:35:18 CET oafedulidis Assigned to capsule by script
10. May 2021 14:00:59 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:17:57 CET jreher Updated box and position via API.
11. Aug 2020 17:41:17 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:29:19 CEST jreher Updated box and position via API.
16. Jan 2020 12:06:01 CET jreher Updated date sent for analysis after screening via API.
16. Jan 2020 12:04:11 CET jreher Updated annealing info via API.
16. Jan 2020 12:01:22 CET jreher Updated irradiation info via API.
16. Jan 2020 11:58:29 CET jreher Updated arrival for irradiation via API.
16. Jan 2020 11:57:28 CET jreher Updated arrival for irradiation via API.
27. Nov 2019 20:09:44 CET jreher Updated APD location via API.
25. Nov 2019 17:28:45 CET jreher Updated box and position via API.
22. Oct 2019 12:54:26 CEST spankonin Updated APD location via API.
18. Oct 2019 14:03:23 CEST jgrochowski Updated APD batch assignment via API.
23. Jun 2016 12:00:14 CEST Tobias Imported from Hamamatsu datasheet.