Show Hamamatsu Avalanche Photo Diode 2318025677 - Archived data from Tue, 22. October 2019 12:54:25 CEST


This is all the information about APD 2318025677. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2318025677
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum Box 230
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: A07
Break-through voltage: 417 V
Voltage for Gain 100 (T=+25°C): 388.1 V
Dark current: 4.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 230
Position in Box: 19
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 150: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 200: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 100: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 150: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 200: T = +20 °C: none     T = -25 °C: none
Break-through voltage: T = +20 °C: none     T = -25 °C: none
   
Notes:


Version history

Time Author Change comment
26. Oct 2021 16:15:11 CEST oafedulidis Assigned to capsule by script
16. Jun 2021 16:04:11 CEST oafedulidis Updated box and position via API.
16. Jun 2021 16:00:24 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:53:04 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:17:55 CET jreher Updated box and position via API.
11. Aug 2020 17:41:14 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:29:18 CEST jreher Updated box and position via API.
16. Jan 2020 12:06:00 CET jreher Updated date sent for analysis after screening via API.
16. Jan 2020 12:04:11 CET jreher Updated annealing info via API.
16. Jan 2020 12:01:21 CET jreher Updated irradiation info via API.
16. Jan 2020 11:58:28 CET jreher Updated arrival for irradiation via API.
16. Jan 2020 11:57:27 CET jreher Updated arrival for irradiation via API.
27. Nov 2019 20:09:43 CET jreher Updated APD location via API.
25. Nov 2019 17:28:44 CET jreher Updated box and position via API.
22. Oct 2019 12:54:25 CEST spankonin Updated APD location via API.
18. Oct 2019 14:02:17 CEST jgrochowski Updated APD batch assignment via API.
23. Jun 2016 12:00:14 CEST Tobias Imported from Hamamatsu datasheet.