Show Hamamatsu Avalanche Photo Diode 2318025676 - Archived data from Tue, 11. August 2020 17:41:14 CEST
This is all the information about APD 2318025676. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 2318025676 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | A11 |
Break-through voltage: | 422 V |
Voltage for Gain 100 (T=+25°C): | 395.1 V |
Dark current: | 6.5 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 230 |
Position in Box: | 18 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | 21. Aug 2019 |
Sent for analysis after irradiation: | 15. Oct 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 09. Oct 2019 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 12. Oct 2019 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 394.9185065 V T = -25 °C: 358.7218304 V |
Voltage for Gain 150: | T = +20 °C: 402.7917881 V T = -25 °C: 366.3368799 V |
Voltage for Gain 200: | T = +20 °C: 407.1543816 V T = -25 °C: 370.6105987 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.603965165 V-1 T = -25 °C: 4.83963747 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.129336838 V-1 T = -25 °C: 8.637622727 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.2275623 V-1 T = -25 °C: 15.52586627 V-1 |
Break-through voltage: | T = +20 °C: 421.5234308 V T = -25 °C: 385.7318532 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:17:55 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:41:14 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:29:18 CEST | jreher | Updated box and position via API. |
16. Jan 2020 12:06:00 CET | jreher | Updated date sent for analysis after screening via API. |
16. Jan 2020 12:04:11 CET | jreher | Updated annealing info via API. |
16. Jan 2020 12:01:21 CET | jreher | Updated irradiation info via API. |
16. Jan 2020 11:58:28 CET | jreher | Updated arrival for irradiation via API. |
16. Jan 2020 11:57:27 CET | jreher | Updated arrival for irradiation via API. |
27. Nov 2019 20:09:43 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:28:44 CET | jreher | Updated box and position via API. |
22. Oct 2019 12:54:25 CEST | spankonin | Updated APD location via API. |
18. Oct 2019 14:02:17 CEST | jgrochowski | Updated APD batch assignment via API. |
23. Jun 2016 12:00:14 CEST | Tobias | Imported from Hamamatsu datasheet. |