RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2318025672 - Archived data from Fri, 27. August 2021 11:14:26 CEST


This is all the information about APD 2318025672. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2318025672
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E11
Break-through voltage: 415 V
Voltage for Gain 100 (T=+25°C): 386.6 V
Dark current: 10.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 230
Position in Box: 14
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 21. Aug 2019
Sent for analysis after irradiation: 15. Oct 2019
Return for assembly: none
   
Irradiation:  
Date: 09. Oct 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 12. Oct 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 386.5656644 V     T = -25 °C: 350.6371331 V
Voltage for Gain 150: T = +20 °C: 394.4830915 V     T = -25 °C: 358.1222153 V
Voltage for Gain 200: T = +20 °C: 398.8721441 V     T = -25 °C: 362.3349749 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.349429833 V-1     T = -25 °C: 4.960583429 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.28459451 V-1     T = -25 °C: 9.185899067 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.49178797 V-1     T = -25 °C: 16.37603687 V-1
Break-through voltage: T = +20 °C: 414.3640367 V     T = -25 °C: 377.6763093 V
   
Notes:


Version history

Time Author Change comment
10. Jun 2022 12:31:10 CEST oafedulidis Assigned to capsule by script
27. Aug 2021 11:14:26 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:17:54 CET jreher Updated box and position via API.
11. Aug 2020 17:41:13 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:29:17 CEST jreher Updated box and position via API.
16. Jan 2020 12:06:00 CET jreher Updated date sent for analysis after screening via API.
16. Jan 2020 12:04:10 CET jreher Updated annealing info via API.
16. Jan 2020 12:01:20 CET jreher Updated irradiation info via API.
16. Jan 2020 11:58:28 CET jreher Updated arrival for irradiation via API.
16. Jan 2020 11:57:27 CET jreher Updated arrival for irradiation via API.
27. Nov 2019 20:09:43 CET jreher Updated APD location via API.
25. Nov 2019 17:28:44 CET jreher Updated box and position via API.
22. Oct 2019 12:54:25 CEST spankonin Updated APD location via API.
18. Oct 2019 14:02:16 CEST jgrochowski Updated APD batch assignment via API.
23. Jun 2016 12:00:13 CEST Tobias Imported from Hamamatsu datasheet.