Show Hamamatsu Avalanche Photo Diode 2318025650 - Archived data from Fri, 29. January 2021 10:25:32 CET
This is all the information about APD 2318025650. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 2318025650 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | assigned to 2318025650/2414027079 |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | blue |
Manufacturer information: | |
Wafer position: | F05 |
Break-through voltage: | 414 V |
Voltage for Gain 100 (T=+25°C): | 384.7 V |
Dark current: | 6.8 nA |
Screening Logistics: | |
Available: | No |
Storage Box: | 221 |
Position in Box: | 46 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | 21. Aug 2019 |
Sent for analysis after irradiation: | 15. Oct 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 09. Oct 2019 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 12. Oct 2019 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 384.7578664 V T = -25 °C: 348.8822704 V |
Voltage for Gain 150: | T = +20 °C: 392.6342708 V T = -25 °C: 356.3481453 V |
Voltage for Gain 200: | T = +20 °C: 397.0067402 V T = -25 °C: 360.532026 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.668643104 V-1 T = -25 °C: 4.904987283 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.236860995 V-1 T = -25 °C: 9.017116642 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.43518824 V-1 T = -25 °C: 16.0115263 V-1 |
Break-through voltage: | T = +20 °C: 412.9679263 V T = -25 °C: 376.2876097 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:16:53 CET | jreher | Updated box and position via API. |
29. Jan 2021 10:25:32 CET | jreher | Assigned to capsule by script |
06. Oct 2020 16:50:48 CEST | jreher | Updated box and position via API. |
11. Aug 2020 17:42:19 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:27:52 CEST | jreher | Updated box and position via API. |
16. Jan 2020 12:05:59 CET | jreher | Updated date sent for analysis after screening via API. |
16. Jan 2020 12:04:10 CET | jreher | Updated annealing info via API. |
16. Jan 2020 12:01:20 CET | jreher | Updated irradiation info via API. |
16. Jan 2020 11:58:28 CET | jreher | Updated arrival for irradiation via API. |
16. Jan 2020 11:57:27 CET | jreher | Updated arrival for irradiation via API. |
27. Nov 2019 20:08:10 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:28:09 CET | jreher | Updated box and position via API. |
22. Oct 2019 16:25:23 CEST | spankonin | Updated APD batch assignment via API. |
22. Oct 2019 16:09:29 CEST | spankonin | Updated APD location via API. |
23. Jun 2016 12:00:13 CEST | Tobias | Imported from Hamamatsu datasheet. |