Show Hamamatsu Avalanche Photo Diode 2318025632 - Archived data from Mon, 17. May 2021 09:15:35 CEST
This is all the information about APD 2318025632. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 2318025632 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | C05 |
Break-through voltage: | 413 V |
Voltage for Gain 100 (T=+25°C): | 383.9 V |
Dark current: | 7.3 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 221 |
Position in Box: | 29 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | 21. Aug 2019 |
Sent for analysis after irradiation: | 15. Oct 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 09. Oct 2019 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 12. Oct 2019 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 383.975385 V T = -25 °C: 348.1480036 V |
Voltage for Gain 150: | T = +20 °C: 391.8747286 V T = -25 °C: 355.6362214 V |
Voltage for Gain 200: | T = +20 °C: 396.2767544 V T = -25 °C: 359.8222158 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.562116047 V-1 T = -25 °C: 4.768380108 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.987557448 V-1 T = -25 °C: 9.672840765 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 13.87722248 V-1 T = -25 °C: 15.3523355 V-1 |
Break-through voltage: | T = +20 °C: 411.8675136 V T = -25 °C: 375.3166356 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
10. Jun 2022 12:21:04 CEST | oafedulidis | Assigned to capsule by script |
17. May 2021 09:15:35 CEST | oafedulidis | Updated box and position via API. |
05. Feb 2021 11:16:51 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:42:16 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:27:50 CEST | jreher | Updated box and position via API. |
16. Jan 2020 12:05:58 CET | jreher | Updated date sent for analysis after screening via API. |
16. Jan 2020 12:04:09 CET | jreher | Updated annealing info via API. |
16. Jan 2020 12:01:19 CET | jreher | Updated irradiation info via API. |
16. Jan 2020 11:58:26 CET | jreher | Updated arrival for irradiation via API. |
16. Jan 2020 11:57:25 CET | jreher | Updated arrival for irradiation via API. |
27. Nov 2019 20:08:08 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:28:08 CET | jreher | Updated box and position via API. |
22. Oct 2019 16:25:00 CEST | spankonin | Updated APD batch assignment via API. |
22. Oct 2019 16:09:28 CEST | spankonin | Updated APD location via API. |
23. Jun 2016 12:00:13 CEST | Tobias | Imported from Hamamatsu datasheet. |