Subdetector specification: | |
---|---|
Serial: | 2318025631 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | D04 |
Break-through voltage: | 414 V |
Voltage for Gain 100 (T=+25°C): | 385.5 V |
Dark current: | 7.2 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 221 |
Position in Box: | 28 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | 21. Aug 2019 |
Sent for analysis after irradiation: | 15. Oct 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 09. Oct 2019 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 12. Oct 2019 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 385.4873777 V T = -25 °C: 349.5137331 V |
Voltage for Gain 150: | T = +20 °C: 393.3970898 V T = -25 °C: 357.0168833 V |
Voltage for Gain 200: | T = +20 °C: 397.7924766 V T = -25 °C: 361.2255534 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.373536926 V-1 T = -25 °C: 4.606397833 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.522906593 V-1 T = -25 °C: 9.279254924 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.69960563 V-1 T = -25 °C: 14.59464295 V-1 |
Break-through voltage: | T = +20 °C: 413.3146953 V T = -25 °C: 376.7020124 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:16:51 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:42:16 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:27:50 CEST | jreher | Updated box and position via API. |
16. Jan 2020 12:05:58 CET | jreher | Updated date sent for analysis after screening via API. |
16. Jan 2020 12:04:08 CET | jreher | Updated annealing info via API. |
16. Jan 2020 12:01:19 CET | jreher | Updated irradiation info via API. |
16. Jan 2020 11:58:25 CET | jreher | Updated arrival for irradiation via API. |
16. Jan 2020 11:57:25 CET | jreher | Updated arrival for irradiation via API. |
27. Nov 2019 20:08:08 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:28:08 CET | jreher | Updated box and position via API. |
22. Oct 2019 16:25:00 CEST | spankonin | Updated APD batch assignment via API. |
22. Oct 2019 16:09:28 CEST | spankonin | Updated APD location via API. |
23. Jun 2016 12:00:13 CEST | Tobias | Imported from Hamamatsu datasheet. |