Show Hamamatsu Avalanche Photo Diode 2317025590 - Archived data from Tue, 08. December 2020 17:17:54 CET
This is all the information about APD 2317025590. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 2317025590 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | assigned to 2317025590/2411026783 |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | blue |
Manufacturer information: | |
Wafer position: | H07 |
Break-through voltage: | 411 V |
Voltage for Gain 100 (T=+25°C): | 383.2 V |
Dark current: | 6.2 nA |
Screening Logistics: | |
Available: | No |
Storage Box: | 216 |
Position in Box: | 45 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | 21. Aug 2019 |
Sent for analysis after irradiation: | 15. Oct 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 09. Oct 2019 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 12. Oct 2019 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 382.4642155 V T = -25 °C: 347.4069635 V |
Voltage for Gain 150: | T = +20 °C: 390.3321286 V T = -25 °C: 354.8197458 V |
Voltage for Gain 200: | T = +20 °C: 394.7062003 V T = -25 °C: 358.966891 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.469797419 V-1 T = -25 °C: 4.80406283 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.776320618 V-1 T = -25 °C: 9.798074878 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 15.40576376 V-1 T = -25 °C: 15.65981722 V-1 |
Break-through voltage: | T = +20 °C: 409.9112856 V T = -25 °C: 374.2830193 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:16:12 CET | jreher | Updated box and position via API. |
08. Dec 2020 17:17:54 CET | jreher | Assigned to capsule by script |
06. Oct 2020 16:53:08 CEST | jreher | Updated box and position via API. |
11. Aug 2020 17:42:09 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:26:59 CEST | jreher | Updated box and position via API. |
16. Jan 2020 12:05:56 CET | jreher | Updated date sent for analysis after screening via API. |
16. Jan 2020 12:04:06 CET | jreher | Updated annealing info via API. |
16. Jan 2020 12:01:16 CET | jreher | Updated irradiation info via API. |
16. Jan 2020 11:58:21 CET | jreher | Updated arrival for irradiation via API. |
16. Jan 2020 11:57:22 CET | jreher | Updated arrival for irradiation via API. |
27. Nov 2019 20:07:13 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:27:46 CET | jreher | Updated box and position via API. |
28. Oct 2019 11:13:09 CET | jreher | Updated APD location via API. |
22. Oct 2019 16:24:34 CEST | spankonin | Updated APD batch assignment via API. |
23. Jun 2016 12:00:11 CEST | Tobias | Imported from Hamamatsu datasheet. |