RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2317025550 - Archived data from Tue, 16. February 2021 12:28:23 CET


This is all the information about APD 2317025550. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2317025550
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: H06
Break-through voltage: 411 V
Voltage for Gain 100 (T=+25°C): 382.2 V
Dark current: 6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 233
Position in Box: 6
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 21. Aug 2019
Sent for analysis after irradiation: 15. Oct 2019
Return for assembly: none
   
Irradiation:  
Date: 09. Oct 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 12. Oct 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 381.9061691 V     T = -25 °C: 346.5306649 V
Voltage for Gain 150: T = +20 °C: 389.8056658 V     T = -25 °C: 353.9743046 V
Voltage for Gain 200: T = +20 °C: 394.2130649 V     T = -25 °C: 358.1640279 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.589229079 V-1     T = -25 °C: 4.68569717 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.075506483 V-1     T = -25 °C: 9.419218444 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.07329416 V-1     T = -25 °C: 14.80140502 V-1
Break-through voltage: T = +20 °C: 407.146371 V     T = -25 °C: 373.8720912 V
   
Notes:


Version history

Time Author Change comment
15. Apr 2021 16:17:54 CEST oafedulidis Assigned to capsule by script
16. Feb 2021 12:28:23 CET jreher Updated box and position via API.
05. Feb 2021 11:18:18 CET jreher Updated box and position via API.
11. Aug 2020 17:41:50 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:29:47 CEST jreher Updated box and position via API.
16. Jan 2020 12:05:53 CET jreher Updated date sent for analysis after screening via API.
16. Jan 2020 12:04:03 CET jreher Updated annealing info via API.
16. Jan 2020 12:01:13 CET jreher Updated irradiation info via API.
16. Jan 2020 11:58:16 CET jreher Updated arrival for irradiation via API.
16. Jan 2020 11:57:19 CET jreher Updated arrival for irradiation via API.
27. Nov 2019 20:10:16 CET jreher Updated APD location via API.
25. Nov 2019 17:28:58 CET jreher Updated box and position via API.
22. Oct 2019 13:08:16 CEST spankonin Updated APD location via API.
18. Oct 2019 14:12:38 CEST jgrochowski Updated APD batch assignment via API.
23. Jun 2016 12:00:10 CEST Tobias Imported from Hamamatsu datasheet.