Show Hamamatsu Avalanche Photo Diode 2317025545 - Archived data from Tue, 31. March 2020 08:52:18 CEST
This is all the information about APD 2317025545. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 2317025545 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | assigned to 2417027266/2317025545 |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | red |
Manufacturer information: | |
Wafer position: | D07 |
Break-through voltage: | 410 V |
Voltage for Gain 100 (T=+25°C): | 380.7 V |
Dark current: | 6 nA |
Screening Logistics: | |
Available: | No |
Storage Box: | 233 |
Position in Box: | 1 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | 21. Aug 2019 |
Sent for analysis after irradiation: | 15. Oct 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 09. Oct 2019 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 12. Oct 2019 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
Break-through voltage: | T = +20 °C: none T = -25 °C: none |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:18:17 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:41:49 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:29:46 CEST | jreher | Updated box and position via API. |
31. Mar 2020 08:52:18 CEST | jreher | Assigned to capsule by script |
13. Feb 2020 13:37:21 CET | jreher | Updated box and position via API. |
16. Jan 2020 12:05:52 CET | jreher | Updated date sent for analysis after screening via API. |
16. Jan 2020 12:04:03 CET | jreher | Updated annealing info via API. |
16. Jan 2020 12:01:13 CET | jreher | Updated irradiation info via API. |
16. Jan 2020 11:58:15 CET | jreher | Updated arrival for irradiation via API. |
16. Jan 2020 11:57:19 CET | jreher | Updated arrival for irradiation via API. |
27. Nov 2019 20:10:15 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:28:57 CET | jreher | Updated box and position via API. |
22. Oct 2019 13:08:15 CEST | spankonin | Updated APD location via API. |
18. Oct 2019 14:12:37 CEST | jgrochowski | Updated APD batch assignment via API. |
23. Jun 2016 12:00:10 CEST | Tobias | Imported from Hamamatsu datasheet. |