RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2315025407 - Archived data from Tue, 11. August 2020 17:42:22 CEST


This is all the information about APD 2315025407. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2315025407
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C03
Break-through voltage: 415 V
Voltage for Gain 100 (T=+25°C): 386.4 V
Dark current: 5.3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 226
Position in Box: 10
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 21. Aug 2019
Sent for analysis after irradiation: 15. Oct 2019
Return for assembly: none
   
Irradiation:  
Date: 09. Oct 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 12. Oct 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 386.3138933 V     T = -25 °C: 350.530283 V
Voltage for Gain 150: T = +20 °C: 394.1814234 V     T = -25 °C: 358.0236047 V
Voltage for Gain 200: T = +20 °C: 398.5594097 V     T = -25 °C: 362.2294007 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.484776122 V-1     T = -25 °C: 4.657275718 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.778640247 V-1     T = -25 °C: 9.300101523 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.28828784 V-1     T = -25 °C: 14.59060431 V-1
Break-through voltage: T = +20 °C: 414.4940319 V     T = -25 °C: 378.0979947 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:17:29 CET jreher Updated box and position via API.
07. Oct 2020 12:16:06 CEST jreher Assigned to capsule by script
17. Aug 2020 15:53:04 CEST jreher Updated box and position via API.
11. Aug 2020 17:42:22 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:28:43 CEST jreher Updated box and position via API.
16. Jan 2020 12:05:47 CET jreher Updated date sent for analysis after screening via API.
16. Jan 2020 12:03:58 CET jreher Updated annealing info via API.
16. Jan 2020 12:01:08 CET jreher Updated irradiation info via API.
16. Jan 2020 11:58:06 CET jreher Updated arrival for irradiation via API.
16. Jan 2020 11:57:13 CET jreher Updated arrival for irradiation via API.
27. Nov 2019 20:09:03 CET jreher Updated APD location via API.
25. Nov 2019 17:28:29 CET jreher Updated box and position via API.
22. Oct 2019 16:25:24 CEST spankonin Updated APD batch assignment via API.
22. Oct 2019 16:10:05 CEST spankonin Updated APD location via API.
23. Jun 2016 12:00:06 CEST Tobias Imported from Hamamatsu datasheet.