RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2315025389 - Archived data from Mon, 17. August 2020 15:53:26 CEST


This is all the information about APD 2315025389. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2315025389
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C07
Break-through voltage: 410 V
Voltage for Gain 100 (T=+25°C): 381.6 V
Dark current: 4.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 231
Position in Box: 48
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 21. Aug 2019
Sent for analysis after irradiation: 15. Oct 2019
Return for assembly: none
   
Irradiation:  
Date: 09. Oct 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 12. Oct 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 381.879108 V     T = -25 °C: 346.3160769 V
Voltage for Gain 150: T = +20 °C: 389.7130423 V     T = -25 °C: 353.6929847 V
Voltage for Gain 200: T = +20 °C: 394.0637702 V     T = -25 °C: 357.8295656 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.650667029 V-1     T = -25 °C: 4.841529557 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.222052071 V-1     T = -25 °C: 9.719482087 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.38504074 V-1     T = -25 °C: 15.53770054 V-1
Break-through voltage: T = +20 °C: 409.8595034 V     T = -25 °C: 373.3403957 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:18:07 CET jreher Updated box and position via API.
07. Oct 2020 12:12:54 CEST jreher Assigned to capsule by script
17. Aug 2020 15:53:26 CEST jreher Updated box and position via API.
11. Aug 2020 17:41:10 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:29:30 CEST jreher Updated box and position via API.
16. Jan 2020 12:05:46 CET jreher Updated date sent for analysis after screening via API.
16. Jan 2020 12:03:57 CET jreher Updated annealing info via API.
16. Jan 2020 12:01:07 CET jreher Updated irradiation info via API.
16. Jan 2020 11:58:04 CET jreher Updated arrival for irradiation via API.
16. Jan 2020 11:57:12 CET jreher Updated arrival for irradiation via API.
27. Nov 2019 20:09:57 CET jreher Updated APD location via API.
25. Nov 2019 17:28:52 CET jreher Updated box and position via API.
22. Oct 2019 13:37:35 CEST spankonin Updated APD location via API.
22. Oct 2019 12:50:41 CEST spankonin Updated APD location via API.
18. Oct 2019 14:02:15 CEST jgrochowski Updated APD batch assignment via API.
23. Jun 2016 11:59:14 CEST Tobias Imported from Hamamatsu datasheet.