Show Hamamatsu Avalanche Photo Diode 2314025357 - Archived data from Tue, 21. July 2020 14:29:29 CEST
This is all the information about APD 2314025357. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 2314025357 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | C11 |
Break-through voltage: | 412 V |
Voltage for Gain 100 (T=+25°C): | 384.1 V |
Dark current: | 4.6 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 231 |
Position in Box: | 32 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | 21. Aug 2019 |
Sent for analysis after irradiation: | 15. Oct 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 09. Oct 2019 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 12. Oct 2019 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
Break-through voltage: | T = +20 °C: none T = -25 °C: none |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:18:05 CET | jreher | Updated box and position via API. |
07. Oct 2020 12:09:35 CEST | jreher | Assigned to capsule by script |
17. Aug 2020 15:53:17 CEST | jreher | Updated box and position via API. |
11. Aug 2020 17:41:08 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:29:29 CEST | jreher | Updated box and position via API. |
16. Jan 2020 12:05:44 CET | jreher | Updated date sent for analysis after screening via API. |
16. Jan 2020 12:03:54 CET | jreher | Updated annealing info via API. |
16. Jan 2020 12:01:04 CET | jreher | Updated irradiation info via API. |
16. Jan 2020 11:58:00 CET | jreher | Updated arrival for irradiation via API. |
16. Jan 2020 11:57:10 CET | jreher | Updated arrival for irradiation via API. |
27. Nov 2019 20:09:56 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:28:50 CET | jreher | Updated box and position via API. |
22. Oct 2019 13:37:33 CEST | spankonin | Updated APD location via API. |
22. Oct 2019 12:50:40 CEST | spankonin | Updated APD location via API. |
18. Oct 2019 13:58:55 CEST | jgrochowski | Updated APD batch assignment via API. |
23. Jun 2016 11:59:14 CEST | Tobias | Imported from Hamamatsu datasheet. |