Show Hamamatsu Avalanche Photo Diode 2314025321 - Archived data from Mon, 17. August 2020 15:54:00 CEST
This is all the information about APD 2314025321. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 2314025321 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | C03 |
Break-through voltage: | 409 V |
Voltage for Gain 100 (T=+25°C): | 380.6 V |
Dark current: | 5.2 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 216 |
Position in Box: | 33 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | 21. Aug 2019 |
Sent for analysis after irradiation: | 15. Oct 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 09. Oct 2019 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 12. Oct 2019 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 380.5753331 V T = -25 °C: 345.3447201 V |
Voltage for Gain 150: | T = +20 °C: 388.4473057 V T = -25 °C: 352.7421343 V |
Voltage for Gain 200: | T = +20 °C: 392.8253816 V T = -25 °C: 356.8969734 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.446004347 V-1 T = -25 °C: 4.813026274 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.576216401 V-1 T = -25 °C: 9.73040285 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.8512733 V-1 T = -25 °C: 15.5043075 V-1 |
Break-through voltage: | T = +20 °C: 408.7936137 V T = -25 °C: 372.5917205 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:16:11 CET | jreher | Updated box and position via API. |
07. Oct 2020 12:18:43 CEST | jreher | Assigned to capsule by script |
17. Aug 2020 15:54:00 CEST | jreher | Updated box and position via API. |
11. Aug 2020 17:42:07 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:26:58 CEST | jreher | Updated box and position via API. |
16. Jan 2020 12:05:41 CET | jreher | Updated date sent for analysis after screening via API. |
16. Jan 2020 12:03:51 CET | jreher | Updated annealing info via API. |
16. Jan 2020 12:01:02 CET | jreher | Updated irradiation info via API. |
16. Jan 2020 11:57:54 CET | jreher | Updated arrival for irradiation via API. |
16. Jan 2020 11:57:06 CET | jreher | Updated arrival for irradiation via API. |
27. Nov 2019 20:07:13 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:27:45 CET | jreher | Updated box and position via API. |
28. Oct 2019 11:13:08 CET | jreher | Updated APD location via API. |
22. Oct 2019 16:24:33 CEST | spankonin | Updated APD batch assignment via API. |
23. Jun 2016 11:59:12 CEST | Tobias | Imported from Hamamatsu datasheet. |