RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2314025318 - Archived data from Thu, 16. January 2020 12:01:01 CET


This is all the information about APD 2314025318. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2314025318
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F07
Break-through voltage: 407 V
Voltage for Gain 100 (T=+25°C): 378.2 V
Dark current: 8.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 23
Position in Box: 45
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 21. Aug 2019
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: 09. Oct 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 150: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 200: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 100: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 150: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 200: T = +20 °C: none     T = -25 °C: none
Break-through voltage: T = +20 °C: none     T = -25 °C: none
   
Notes:


Version history

Time Author Change comment
29. Mar 2022 12:39:11 CEST oafedulidis Assigned to capsule by script
16. Jun 2021 16:03:08 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:59:33 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:52:10 CEST oafedulidis Updated box and position via API.
26. Apr 2021 14:28:04 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:16:10 CET jreher Updated box and position via API.
11. Aug 2020 17:42:06 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:26:58 CEST jreher Updated box and position via API.
16. Jan 2020 12:05:41 CET jreher Updated date sent for analysis after screening via API.
16. Jan 2020 12:03:51 CET jreher Updated annealing info via API.
16. Jan 2020 12:01:01 CET jreher Updated irradiation info via API.
16. Jan 2020 11:57:54 CET jreher Updated arrival for irradiation via API.
16. Jan 2020 11:57:06 CET jreher Updated arrival for irradiation via API.
27. Nov 2019 20:07:12 CET jreher Updated APD location via API.
25. Nov 2019 17:27:44 CET jreher Updated box and position via API.
28. Oct 2019 11:13:08 CET jreher Updated APD location via API.
22. Oct 2019 16:22:41 CEST spankonin Updated APD batch assignment via API.
23. Jun 2016 11:59:12 CEST Tobias Imported from Hamamatsu datasheet.