RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2314025309 - Archived data from Tue, 11. August 2020 17:42:05 CEST


This is all the information about APD 2314025309. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2314025309
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E15
Break-through voltage: 410 V
Voltage for Gain 100 (T=+25°C): 384.6 V
Dark current: 5.3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 23
Position in Box: 40
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 21. Aug 2019
Sent for analysis after irradiation: 15. Oct 2019
Return for assembly: none
   
Irradiation:  
Date: 09. Oct 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 12. Oct 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 383.3291805 V     T = -25 °C: 347.7186333 V
Voltage for Gain 150: T = +20 °C: 391.2046222 V     T = -25 °C: 355.1575974 V
Voltage for Gain 200: T = +20 °C: 395.5770217 V     T = -25 °C: 359.3323732 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.474495501 V-1     T = -25 °C: 4.945259185 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.691831873 V-1     T = -25 °C: 9.234195627 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.23061859 V-1     T = -25 °C: 14.49413038 V-1
Break-through voltage: T = +20 °C: 409.3291951 V     T = -25 °C: 373.1303392 V
   
Notes:


Version history

Time Author Change comment
26. Apr 2021 14:28:03 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:16:09 CET jreher Updated box and position via API.
11. Aug 2020 17:42:05 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:26:57 CEST jreher Updated box and position via API.
16. Jan 2020 12:05:40 CET jreher Updated date sent for analysis after screening via API.
16. Jan 2020 12:03:51 CET jreher Updated annealing info via API.
16. Jan 2020 12:01:01 CET jreher Updated irradiation info via API.
16. Jan 2020 11:57:52 CET jreher Updated arrival for irradiation via API.
16. Jan 2020 11:57:05 CET jreher Updated arrival for irradiation via API.
27. Nov 2019 20:07:12 CET jreher Updated APD location via API.
25. Nov 2019 17:27:44 CET jreher Updated box and position via API.
28. Oct 2019 11:13:07 CET jreher Updated APD location via API.
22. Oct 2019 16:22:40 CEST spankonin Updated APD batch assignment via API.
23. Jun 2016 11:59:12 CEST Tobias Imported from Hamamatsu datasheet.