RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0721006952 - Archived data from Wed, 07. October 2020 14:22:33 CEST


This is all the information about APD 0721006952. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0721006952
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 0721006952/2517028886
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: blue
   
Manufacturer information:  
Wafer position: E03
Break-through voltage: 410 V
Voltage for Gain 100 (T=+25°C): 380.8 V
Dark current: 5.9 nA
   
Screening Logistics:  
Available: No
Storage Box: 52
Position in Box: 40
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 18. Apr 2019
Sent for analysis after irradiation: 04. Jun 2019
Return for assembly: none
   
Irradiation:  
Date: 29. May 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 29. May 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 381.1453888 V     T = -25 °C: 346.2488513 V
Voltage for Gain 150: T = +20 °C: 389.0676036 V     T = -25 °C: 353.4964895 V
Voltage for Gain 200: T = +20 °C: 393.4288946 V     T = -25 °C: 357.6798913 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.498812803 V-1     T = -25 °C: 5.45471344 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.661128839 V-1     T = -25 °C: 9.197772143 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.91576447 V-1     T = -25 °C: 14.27820288 V-1
Break-through voltage: T = +20 °C: 409.3250911 V     T = -25 °C: 373.0885018 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:55:04 CET jreher Updated box and position via API.
03. Feb 2021 18:20:39 CET jreher Updated box and position via API.
07. Oct 2020 14:22:33 CEST jreher Assigned to capsule by script
17. Aug 2020 15:53:53 CEST jreher Updated box and position via API.
11. Aug 2020 17:27:33 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:37:55 CET jreher Updated APD location via API.
25. Nov 2019 17:15:02 CET jreher Updated box and position via API.
04. Jul 2019 11:12:19 CEST jreher Updated APD location via API.
17. Jun 2019 17:51:00 CEST spankonin Updated APD batch assignment via API.
04. Jun 2019 15:27:20 CEST markus.moritz
22. Jun 2016 15:13:22 CEST Tobias Imported from Hamamatsu datasheet.