Show Hamamatsu Avalanche Photo Diode 2313025273 - Archived data from Tue, 16. February 2021 12:26:22 CET
This is all the information about APD 2313025273. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 2313025273 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | C03 |
Break-through voltage: | 414 V |
Voltage for Gain 100 (T=+25°C): | 385.8 V |
Dark current: | 3.7 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 233 |
Position in Box: | 47 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | 21. Aug 2019 |
Sent for analysis after irradiation: | 15. Oct 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 09. Oct 2019 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 12. Oct 2019 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 385.4759724 V T = -25 °C: 349.7611268 V |
Voltage for Gain 150: | T = +20 °C: 393.3622544 V T = -25 °C: 357.2661623 V |
Voltage for Gain 200: | T = +20 °C: 397.7440646 V T = -25 °C: 361.4945446 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.443588103 V-1 T = -25 °C: 4.922435811 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.632771575 V-1 T = -25 °C: 9.116898464 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.96326737 V-1 T = -25 °C: 16.09072697 V-1 |
Break-through voltage: | T = +20 °C: 413.888647 V T = -25 °C: 377.5536917 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
29. Apr 2021 17:02:53 CEST | oafedulidis | Assigned to capsule by script |
16. Feb 2021 12:26:22 CET | jreher | Updated box and position via API. |
05. Feb 2021 11:18:22 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:41:58 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:29:50 CEST | jreher | Updated box and position via API. |
16. Jan 2020 12:05:38 CET | jreher | Updated date sent for analysis after screening via API. |
16. Jan 2020 12:03:49 CET | jreher | Updated annealing info via API. |
16. Jan 2020 12:00:59 CET | jreher | Updated irradiation info via API. |
16. Jan 2020 11:57:49 CET | jreher | Updated arrival for irradiation via API. |
16. Jan 2020 11:57:03 CET | jreher | Updated arrival for irradiation via API. |
27. Nov 2019 20:10:19 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:29:01 CET | jreher | Updated box and position via API. |
22. Oct 2019 13:08:19 CEST | spankonin | Updated APD location via API. |
18. Oct 2019 14:14:34 CEST | jgrochowski | Updated APD batch assignment via API. |
23. Jun 2016 11:59:11 CEST | Tobias | Imported from Hamamatsu datasheet. |