RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2313025229


This is all the information about APD 2313025229. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2313025229
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2403026074/2313025229
Unit: #1030 (barcode 1309011278)
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: red
   
Manufacturer information:  
Wafer position: C05
Break-through voltage: 412 V
Voltage for Gain 100 (T=+25°C): 384 V
Dark current: 3 nA
   
Screening Logistics:  
Available: No
Storage Box: 46
Position in Box: 4
EP1 batch: none
EP1 batch after irradiation: 10075
   
Shipment:  
Grid number: 694
Position in grid: 10
Arrival for irradiation: 11. Aug 2016
Sent for analysis after irradiation: 02. Sep 2016
Return for assembly: 15. Nov 2016
   
Irradiation:  
Date: 23. Aug 2016
Dose used: 30 Gy
Temperature: 25 °C
Position: 4
Bias voltage: 350 V     (connected)
   
Annealing:  
Date: 24. Aug 2016
Temperature: 80 °C
Duration: 10 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 384.0336432 V     T = -25 °C: 348.482728 V
Voltage for Gain 150: T = +20 °C: 391.8638735 V     T = -25 °C: 355.8828655 V
Voltage for Gain 200: T = +20 °C: 396.2344425 V     T = -25 °C: 360.0307904 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.43085545 V-1     T = -25 °C: 4.724785796 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.037698974 V-1     T = -25 °C: 9.369388424 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.35994571 V-1     T = -25 °C: 14.95295687 V-1
Break-through voltage: T = +20 °C: 411.8736466 V     T = -25 °C: 375.4353551 V
   
Notes:


Characteristics

Temperature Measurement Notes
No characteristics available!


Upload new characteristic...

Progression of the current during irradiation

Upload time Notes
No data available!


Upload new progression data...

Version history

Time Author Change comment
05. Feb 2021 10:54:04 CET jreher Updated box and position via API.
03. Feb 2021 18:19:50 CET jreher Updated box and position via API.
11. Aug 2020 17:27:08 CEST jreher Updated APD characteristics via API.
03. Apr 2020 09:45:22 CEST jreher Assigned to capsule by script
13. Feb 2020 14:23:21 CET jreher Updated box and position via API.
27. Nov 2019 19:37:08 CET jreher Updated APD location via API.
25. Nov 2019 17:14:32 CET jreher Updated box and position via API.
04. Jul 2019 11:11:51 CEST jreher Updated APD location via API.
18. Jun 2019 13:30:06 CEST jgrochowski Updated APD batch assignment via API.
15. Nov 2016 11:26:04 CET markus.moritz Entered return for assembly date.
08. Sep 2016 13:37:59 CEST markus.moritz Entered shipped after irradiation date.
24. Aug 2016 14:28:57 CEST christopher.l.hahn Entered irradiation information.
24. Aug 2016 14:26:53 CEST christopher.l.hahn Entered annealing information.
11. Aug 2016 11:49:06 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:52:18 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 11:59:10 CEST Tobias Imported from Hamamatsu datasheet.