Subdetector specification:  
Serial: 0721006945
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 0721006945/2418027360
Unit: #859 (barcode 1309009428)
Preamp: 4359
Current location: Bochum
   
Installation information:  
Label: blue
   
Manufacturer information:  
Wafer position: E05
Break-through voltage: 410 V
Voltage for Gain 100 (T=+25°C): 380.7 V
Dark current: 22.7 nA
   
Screening Logistics:  
Available: No
Storage Box: 52
Position in Box: 33
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 18. Apr 2019
Sent for analysis after irradiation: 04. Jun 2019
Return for assembly: none
   
Irradiation:  
Date: 29. May 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 29. May 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 380.8505123 V     T = -25 °C: 345.7473642 V
Voltage for Gain 150: T = +20 °C: 388.7101469 V     T = -25 °C: 353.0339414 V
Voltage for Gain 200: T = +20 °C: 393.1362614 V     T = -25 °C: 357.2062545 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.616122177 V-1     T = -25 °C: 5.396262988 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.471572173 V-1     T = -25 °C: 9.601021489 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.20465832 V-1     T = -25 °C: 14.95098791 V-1
Break-through voltage: T = +20 °C: 409.3860655 V     T = -25 °C: 372.9052947 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:55:03 CET jreher Updated box and position via API.
03. Feb 2021 18:20:38 CET jreher Updated box and position via API.
11. Aug 2020 17:27:32 CEST jreher Updated APD characteristics via API.
13. Feb 2020 14:42:51 CET jreher Updated box and position via API.
27. Nov 2019 19:37:54 CET jreher Updated APD location via API.
25. Nov 2019 17:15:01 CET jreher Updated box and position via API.
17. Oct 2019 14:07:02 CEST tholtmann Assigned to unit by script
17. Oct 2019 13:49:28 CEST tholtmann Assigned to capsule by script
04. Jul 2019 11:12:19 CEST jreher Updated APD location via API.
17. Jun 2019 17:50:59 CEST spankonin Updated APD batch assignment via API.
04. Jun 2019 15:24:00 CEST markus.moritz