RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0721006944 - Archived data from Wed, 03. February 2021 18:20:38 CET


This is all the information about APD 0721006944. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0721006944
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 0823008959/0721006944
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: red
   
Manufacturer information:  
Wafer position: D09
Break-through voltage: 415 V
Voltage for Gain 100 (T=+25°C): 386.2 V
Dark current: 8.4 nA
   
Screening Logistics:  
Available: No
Storage Box: 52
Position in Box: 32
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 18. Apr 2019
Sent for analysis after irradiation: 04. Jun 2019
Return for assembly: none
   
Irradiation:  
Date: 29. May 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 29. May 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 386.3497681 V     T = -25 °C: 350.5761092 V
Voltage for Gain 150: T = +20 °C: 394.2756993 V     T = -25 °C: 358.0096368 V
Voltage for Gain 200: T = +20 °C: 398.7066588 V     T = -25 °C: 362.2358302 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.776778205 V-1     T = -25 °C: 5.289591536 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.459873142 V-1     T = -25 °C: 9.094437299 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.06570632 V-1     T = -25 °C: 16.56128839 V-1
Break-through voltage: T = +20 °C: 414.7356297 V     T = -25 °C: 377.962011 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:55:03 CET jreher Updated box and position via API.
03. Feb 2021 18:20:38 CET jreher Updated box and position via API.
07. Oct 2020 12:16:09 CEST jreher Assigned to capsule by script
17. Aug 2020 15:53:04 CEST jreher Updated box and position via API.
11. Aug 2020 17:27:31 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:37:54 CET jreher Updated APD location via API.
25. Nov 2019 17:15:01 CET jreher Updated box and position via API.
04. Jul 2019 11:12:19 CEST jreher Updated APD location via API.
17. Jun 2019 17:50:59 CEST spankonin Updated APD batch assignment via API.
04. Jun 2019 15:23:20 CEST markus.moritz
22. Jun 2016 15:13:22 CEST Tobias Imported from Hamamatsu datasheet.