RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0720006914 - Archived data from Wed, 03. February 2021 18:20:36 CET


This is all the information about APD 0720006914. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0720006914
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E09
Break-through voltage: 416 V
Voltage for Gain 100 (T=+25°C): 387.1 V
Dark current: 12.4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 52
Position in Box: 9
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 18. Apr 2019
Sent for analysis after irradiation: 04. Jun 2019
Return for assembly: none
   
Irradiation:  
Date: 29. May 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 29. May 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 387.2368732 V     T = -25 °C: 351.5899399 V
Voltage for Gain 150: T = +20 °C: 395.1733188 V     T = -25 °C: 359.0921598 V
Voltage for Gain 200: T = +20 °C: 399.5927597 V     T = -25 °C: 363.333704 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.604924745 V-1     T = -25 °C: 4.802970729 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.851066569 V-1     T = -25 °C: 9.339689178 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.86248905 V-1     T = -25 °C: 15.85900458 V-1
Break-through voltage: T = +20 °C: 414.9525458 V     T = -25 °C: 378.5951404 V
   
Notes:


Version history

Time Author Change comment
16. Nov 2021 10:41:44 CET oafedulidis Assigned to capsule by script
27. Aug 2021 10:31:12 CEST oafedulidis Updated box and position via API.
21. Apr 2021 14:48:24 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:55:00 CET jreher Updated box and position via API.
03. Feb 2021 18:20:36 CET jreher Updated box and position via API.
11. Aug 2020 17:27:27 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:37:52 CET jreher Updated APD location via API.
25. Nov 2019 17:15:00 CET jreher Updated box and position via API.
04. Jul 2019 11:12:17 CEST jreher Updated APD location via API.
18. Jun 2019 13:34:40 CEST jgrochowski Updated APD batch assignment via API.
04. Jun 2019 15:12:13 CEST markus.moritz
22. Jun 2016 15:13:21 CEST Tobias Imported from Hamamatsu datasheet.