Subdetector specification:  
Serial: 2309024909
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B13
Break-through voltage: 412 V
Voltage for Gain 100 (T=+25°C): 383.7 V
Dark current: 4.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 351
Position in Box: 29
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 383.1436873 V     T = -25 °C: 347.8751999 V
Voltage for Gain 150: T = +20 °C: 390.9976249 V     T = -25 °C: 355.3046947 V
Voltage for Gain 200: T = +20 °C: 395.3749814 V     T = -25 °C: 359.4830608 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.557970975 V-1     T = -25 °C: 4.951957907 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.986738875 V-1     T = -25 °C: 9.15012746 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.96388114 V-1     T = -25 °C: 16.26726534 V-1
Break-through voltage: T = +20 °C: 403.2646771 V     T = -25 °C: 375.0480545 V
   
Notes:


Version history

Time Author Change comment
29. Apr 2021 17:03:54 CEST oafedulidis Assigned to capsule by script
16. Apr 2021 22:00:27 CEST jreher Updated APD characteristics via API.
16. Feb 2021 12:28:44 CET jreher Updated box and position via API.
05. Feb 2021 11:33:20 CET jreher Updated box and position via API.
08. Oct 2020 18:14:27 CEST jreher Updated APD location via API.
17. Aug 2020 14:18:00 CEST vwerner Updated APD batch assignment via API.
23. Jun 2016 11:58:14 CEST Tobias Imported from Hamamatsu datasheet.