RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2016022577 - Archived data from Fri, 16. April 2021 22:00:52 CEST


This is all the information about APD 2016022577. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2016022577
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B04
Break-through voltage: 405 V
Voltage for Gain 100 (T=+25°C): 376.5 V
Dark current: 14.2 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 355
Position in Box: 2
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 376.9830682 V     T = -25 °C: 342.7320448 V
Voltage for Gain 150: T = +20 °C: 384.6572437 V     T = -25 °C: 349.8408388 V
Voltage for Gain 200: T = +20 °C: 388.9467566 V     T = -25 °C: 353.8406037 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.703548825 V-1     T = -25 °C: 5.22260191 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.409568253 V-1     T = -25 °C: 9.971854384 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.78328922 V-1     T = -25 °C: 15.99819939 V-1
Break-through voltage: T = +20 °C: 404.2459553 V     T = -25 °C: 368.5889588 V
   
Notes:


Version history

Time Author Change comment
21. Apr 2021 14:46:42 CEST oafedulidis Updated box and position via API.
16. Apr 2021 22:00:52 CEST jreher Updated APD characteristics via API.
05. Feb 2021 11:33:48 CET jreher Updated box and position via API.
08. Oct 2020 18:15:10 CEST jreher Updated APD location via API.
17. Aug 2020 14:25:44 CEST vwerner Updated APD batch assignment via API.
23. Jun 2016 11:54:00 CEST Tobias Imported from Hamamatsu datasheet.