Show Hamamatsu Avalanche Photo Diode 2010022227 - Archived data from Tue, 11. August 2020 17:41:40 CEST
This is all the information about APD 2010022227. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 2010022227 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | D07 |
Break-through voltage: | 404 V |
Voltage for Gain 100 (T=+25°C): | 375.7 V |
Dark current: | 19.5 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 225 |
Position in Box: | 6 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | 21. Aug 2019 |
Sent for analysis after irradiation: | 15. Oct 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 09. Oct 2019 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 12. Oct 2019 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 376.0729644 V T = -25 °C: 342.0767544 V |
Voltage for Gain 150: | T = +20 °C: 383.7066804 V T = -25 °C: 349.1730307 V |
Voltage for Gain 200: | T = +20 °C: 387.974267 V T = -25 °C: 353.1584662 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.734795034 V-1 T = -25 °C: 5.096077353 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.46345325 V-1 T = -25 °C: 9.736984021 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.86871759 V-1 T = -25 °C: 15.54413773 V-1 |
Break-through voltage: | T = +20 °C: 403.6011371 V T = -25 °C: 368.0286274 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:17:20 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:41:40 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:28:33 CEST | jreher | Updated box and position via API. |
16. Jan 2020 12:06:40 CET | jreher | Updated date sent for analysis after screening via API. |
16. Jan 2020 12:04:50 CET | jreher | Updated annealing info via API. |
16. Jan 2020 12:02:00 CET | jreher | Updated irradiation info via API. |
16. Jan 2020 11:59:08 CET | jreher | Updated arrival for irradiation via API. |
16. Jan 2020 11:58:25 CET | jreher | Updated arrival for irradiation via API. |
27. Nov 2019 20:08:51 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:28:25 CET | jreher | Updated box and position via API. |
22. Oct 2019 12:57:26 CEST | spankonin | Updated APD location via API. |
18. Oct 2019 14:10:16 CEST | jgrochowski | Updated APD batch assignment via API. |
23. Jun 2016 11:53:51 CEST | Tobias | Imported from Hamamatsu datasheet. |