Serial: 2007022011
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2007022011/2504027836
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: blue
   
Manufacturer information:  
Wafer position: F11
Break-through voltage: 408 V
Voltage for Gain 100 (T=+25°C): 379.3 V
Dark current: 26.5 nA
   
Screening Logistics:  
Available: No
Storage Box: 231
Position in Box: 1
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 21. Aug 2019
Sent for analysis after irradiation: 15. Oct 2019
Return for assembly: none
   
Irradiation:  
Date: 09. Oct 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 12. Oct 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 150: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 200: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 100: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 150: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 200: T = +20 °C: none     T = -25 °C: none
Break-through voltage: T = +20 °C: none     T = -25 °C: none
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:18:01 CET jreher Updated box and position via API.
11. Aug 2020 17:41:01 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:29:26 CEST jreher Updated box and position via API.
31. Mar 2020 08:53:32 CEST jreher Assigned to capsule by script
13. Feb 2020 14:23:11 CET jreher Updated box and position via API.
16. Jan 2020 12:06:28 CET jreher Updated date sent for analysis after screening via API.
16. Jan 2020 12:04:39 CET jreher Updated annealing info via API.
16. Jan 2020 12:01:49 CET jreher Updated irradiation info via API.
16. Jan 2020 11:58:57 CET jreher Updated arrival for irradiation via API.
16. Jan 2020 11:58:04 CET jreher Updated arrival for irradiation via API.
27. Nov 2019 20:09:53 CET jreher Updated APD location via API.
25. Nov 2019 17:28:48 CET jreher Updated box and position via API.
22. Oct 2019 13:37:31 CEST spankonin Updated APD location via API.
22. Oct 2019 12:50:37 CEST spankonin Updated APD location via API.
18. Oct 2019 13:57:51 CEST jgrochowski Updated APD batch assignment via API.
23. Jun 2016 11:52:50 CEST Tobias Imported from Hamamatsu datasheet.