Subdetector specification:  
Serial: 2007021997
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C13
Break-through voltage: 410 V
Voltage for Gain 100 (T=+25°C): 381.2 V
Dark current: 16.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 235
Position in Box: 38
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 21. Aug 2019
Sent for analysis after irradiation: 15. Oct 2019
Return for assembly: none
   
Irradiation:  
Date: 09. Oct 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 12. Oct 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 381.6603056 V     T = -25 °C: 346.7761618 V
Voltage for Gain 150: T = +20 °C: 389.4575142 V     T = -25 °C: 354.0497383 V
Voltage for Gain 200: T = +20 °C: 393.79577 V     T = -25 °C: 358.1475357 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.423384922 V-1     T = -25 °C: 5.086419392 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.581285725 V-1     T = -25 °C: 9.531293457 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.82876748 V-1     T = -25 °C: 15.03258802 V-1
Break-through voltage: T = +20 °C: 409.3510378 V     T = -25 °C: 373.2871244 V
   
Notes:


Version history

Time Author Change comment
09. Feb 2021 11:21:39 CET jreher Assigned to capsule by script
05. Feb 2021 11:18:37 CET jreher Updated box and position via API.
18. Dec 2020 13:59:41 CET jreher Updated box and position via API.
11. Aug 2020 17:40:59 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:30:11 CEST jreher Updated box and position via API.
16. Jan 2020 12:06:27 CET jreher Updated date sent for analysis after screening via API.
16. Jan 2020 12:04:38 CET jreher Updated annealing info via API.
16. Jan 2020 12:01:48 CET jreher Updated irradiation info via API.
16. Jan 2020 11:58:56 CET jreher Updated arrival for irradiation via API.
16. Jan 2020 11:58:02 CET jreher Updated arrival for irradiation via API.
27. Nov 2019 20:10:40 CET jreher Updated APD location via API.
25. Nov 2019 17:29:10 CET jreher Updated box and position via API.
22. Oct 2019 12:49:12 CEST spankonin Updated APD location via API.
18. Oct 2019 13:57:50 CEST jgrochowski Updated APD batch assignment via API.
23. Jun 2016 11:52:49 CEST Tobias Imported from Hamamatsu datasheet.