Serial: 2006021904
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: A08
Break-through voltage: 405 V
Voltage for Gain 100 (T=+25°C): 376.6 V
Dark current: 22.2 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 235
Position in Box: 7
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 21. Aug 2019
Sent for analysis after irradiation: 15. Oct 2019
Return for assembly: none
   
Irradiation:  
Date: 09. Oct 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 12. Oct 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 377.1430645 V     T = -25 °C: 342.7017296 V
Voltage for Gain 150: T = +20 °C: 384.8741186 V     T = -25 °C: 349.9038885 V
Voltage for Gain 200: T = +20 °C: 389.2036917 V     T = -25 °C: 353.9628801 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.664217986 V-1     T = -25 °C: 4.790197055 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.158628099 V-1     T = -25 °C: 9.807149777 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.29866992 V-1     T = -25 °C: 15.64334643 V-1
Break-through voltage: T = +20 °C: 404.4367392 V     T = -25 °C: 368.7360724 V
   
Notes:


Version history

Time Author Change comment
15. Nov 2022 09:32:26 CET oafedulidis Assigned to capsule by script
09. Dec 2021 13:11:22 CET oafedulidis Updated box and position via API.
05. Feb 2021 11:18:33 CET jreher Updated box and position via API.
11. Aug 2020 17:40:52 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:30:08 CEST jreher Updated box and position via API.
16. Jan 2020 12:06:25 CET jreher Updated date sent for analysis after screening via API.
16. Jan 2020 12:04:35 CET jreher Updated annealing info via API.
16. Jan 2020 12:01:46 CET jreher Updated irradiation info via API.
16. Jan 2020 11:58:53 CET jreher Updated arrival for irradiation via API.
16. Jan 2020 11:57:58 CET jreher Updated arrival for irradiation via API.
27. Nov 2019 20:10:38 CET jreher Updated APD location via API.
25. Nov 2019 17:29:07 CET jreher Updated box and position via API.
22. Oct 2019 12:49:09 CEST spankonin Updated APD location via API.
18. Oct 2019 13:56:19 CEST jgrochowski Updated APD batch assignment via API.
23. Jun 2016 11:52:48 CEST Tobias Imported from Hamamatsu datasheet.