Show Hamamatsu Avalanche Photo Diode 2006021904 - Archived data from Thu, 16. January 2020 11:58:53 CET
This is all the information about APD 2006021904. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 2006021904 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | A08 |
Break-through voltage: | 405 V |
Voltage for Gain 100 (T=+25°C): | 376.6 V |
Dark current: | 22.2 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 235 |
Position in Box: | 7 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | 21. Aug 2019 |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
Break-through voltage: | T = +20 °C: none T = -25 °C: none |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
15. Nov 2022 09:32:26 CET | oafedulidis | Assigned to capsule by script |
09. Dec 2021 13:11:22 CET | oafedulidis | Updated box and position via API. |
05. Feb 2021 11:18:33 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:40:52 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:30:08 CEST | jreher | Updated box and position via API. |
16. Jan 2020 12:06:25 CET | jreher | Updated date sent for analysis after screening via API. |
16. Jan 2020 12:04:35 CET | jreher | Updated annealing info via API. |
16. Jan 2020 12:01:46 CET | jreher | Updated irradiation info via API. |
16. Jan 2020 11:58:53 CET | jreher | Updated arrival for irradiation via API. |
16. Jan 2020 11:57:58 CET | jreher | Updated arrival for irradiation via API. |
27. Nov 2019 20:10:38 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:29:07 CET | jreher | Updated box and position via API. |
22. Oct 2019 12:49:09 CEST | spankonin | Updated APD location via API. |
18. Oct 2019 13:56:19 CEST | jgrochowski | Updated APD batch assignment via API. |
23. Jun 2016 11:52:48 CEST | Tobias | Imported from Hamamatsu datasheet. |