RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2006021897 - Archived data from Tue, 11. August 2020 17:40:51 CEST


This is all the information about APD 2006021897. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2006021897
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G07
Break-through voltage: 405 V
Voltage for Gain 100 (T=+25°C): 376.7 V
Dark current: 15.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 235
Position in Box: 1
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 21. Aug 2019
Sent for analysis after irradiation: 15. Oct 2019
Return for assembly: none
   
Irradiation:  
Date: 09. Oct 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 12. Oct 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 376.8106831 V     T = -25 °C: 342.4630124 V
Voltage for Gain 150: T = +20 °C: 384.5260955 V     T = -25 °C: 349.6469523 V
Voltage for Gain 200: T = +20 °C: 388.838519 V     T = -25 °C: 353.6709296 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.784291981 V-1     T = -25 °C: 4.899008103 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.643228694 V-1     T = -25 °C: 10.1386591 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.94084529 V-1     T = -25 °C: 16.35631639 V-1
Break-through voltage: T = +20 °C: 404.1069987 V     T = -25 °C: 368.3801572 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:18:33 CET jreher Updated box and position via API.
11. Aug 2020 17:40:51 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:30:08 CEST jreher Updated box and position via API.
16. Jan 2020 12:06:24 CET jreher Updated date sent for analysis after screening via API.
16. Jan 2020 12:04:35 CET jreher Updated annealing info via API.
16. Jan 2020 12:01:45 CET jreher Updated irradiation info via API.
16. Jan 2020 11:58:52 CET jreher Updated arrival for irradiation via API.
16. Jan 2020 11:57:57 CET jreher Updated arrival for irradiation via API.
27. Nov 2019 20:10:37 CET jreher Updated APD location via API.
25. Nov 2019 17:29:07 CET jreher Updated box and position via API.
22. Oct 2019 12:49:09 CEST spankonin Updated APD location via API.
18. Oct 2019 13:56:18 CEST jgrochowski Updated APD batch assignment via API.
23. Jun 2016 11:52:48 CEST Tobias Imported from Hamamatsu datasheet.