Show Hamamatsu Avalanche Photo Diode 2006021895 - Archived data from Tue, 11. August 2020 17:43:28 CEST
This is all the information about APD 2006021895. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 2006021895 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | E10 |
Break-through voltage: | 405 V |
Voltage for Gain 100 (T=+25°C): | 376.4 V |
Dark current: | 9.6 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 259 |
Position in Box: | 49 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | 21. Aug 2019 |
Sent for analysis after irradiation: | 15. Oct 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 09. Oct 2019 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 12. Oct 2019 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 377.2564625 V T = -25 °C: 342.8781949 V |
Voltage for Gain 150: | T = +20 °C: 384.9191528 V T = -25 °C: 350.0558485 V |
Voltage for Gain 200: | T = +20 °C: 389.214454 V T = -25 °C: 354.0754289 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.649065823 V-1 T = -25 °C: 5.132343443 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.22000219 V-1 T = -25 °C: 9.657943954 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.31823679 V-1 T = -25 °C: 15.50216969 V-1 |
Break-through voltage: | T = +20 °C: 404.5756633 V T = -25 °C: 369.0319349 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
19. May 2022 15:28:44 CEST | oafedulidis | Assigned to capsule by script |
28. Apr 2021 13:28:41 CEST | oafedulidis | Updated box and position via API. |
05. Feb 2021 11:21:42 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:43:28 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:34:09 CEST | jreher | Updated box and position via API. |
16. Jan 2020 12:06:24 CET | jreher | Updated date sent for analysis after screening via API. |
16. Jan 2020 12:04:35 CET | jreher | Updated annealing info via API. |
16. Jan 2020 12:01:45 CET | jreher | Updated irradiation info via API. |
16. Jan 2020 11:58:52 CET | jreher | Updated arrival for irradiation via API. |
16. Jan 2020 11:57:56 CET | jreher | Updated arrival for irradiation via API. |
27. Nov 2019 20:14:38 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:30:29 CET | jreher | Updated box and position via API. |
22. Oct 2019 16:38:05 CEST | spankonin | Updated APD batch assignment via API. |
22. Oct 2019 16:18:37 CEST | spankonin | Updated APD location via API. |
23. Jun 2016 11:52:48 CEST | Tobias | Imported from Hamamatsu datasheet. |