RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2006021894 - Archived data from Fri, 05. February 2021 11:19:37 CET


This is all the information about APD 2006021894. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2006021894
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B08
Break-through voltage: 404 V
Voltage for Gain 100 (T=+25°C): 375.5 V
Dark current: 17.9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 243
Position in Box: 18
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 21. Aug 2019
Sent for analysis after irradiation: 15. Oct 2019
Return for assembly: none
   
Irradiation:  
Date: 09. Oct 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 12. Oct 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 376.0901645 V     T = -25 °C: 341.585309 V
Voltage for Gain 150: T = +20 °C: 383.7473911 V     T = -25 °C: 348.7464274 V
Voltage for Gain 200: T = +20 °C: 388.0295177 V     T = -25 °C: 352.774595 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.70486657 V-1     T = -25 °C: 4.85360845 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.380171904 V-1     T = -25 °C: 9.986861413 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.61536303 V-1     T = -25 °C: 16.05644011 V-1
Break-through voltage: T = +20 °C: 403.5653975 V     T = -25 °C: 367.8365056 V
   
Notes:


Version history

Time Author Change comment
26. Oct 2021 10:09:42 CEST oafedulidis Assigned to capsule by script
15. Apr 2021 17:01:29 CEST jreher Updated box and position via API.
05. Feb 2021 11:19:37 CET jreher Updated box and position via API.
11. Aug 2020 17:43:43 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:31:24 CEST jreher Updated box and position via API.
16. Jan 2020 12:06:24 CET jreher Updated date sent for analysis after screening via API.
16. Jan 2020 12:04:34 CET jreher Updated annealing info via API.
16. Jan 2020 12:01:45 CET jreher Updated irradiation info via API.
16. Jan 2020 11:58:52 CET jreher Updated arrival for irradiation via API.
16. Jan 2020 11:57:56 CET jreher Updated arrival for irradiation via API.
27. Nov 2019 20:11:58 CET jreher Updated APD location via API.
25. Nov 2019 17:29:36 CET jreher Updated box and position via API.
31. Oct 2019 17:09:01 CET spankonin Updated APD batch assignment via API.
22. Oct 2019 16:20:39 CEST spankonin Updated APD location via API.
23. Jun 2016 11:52:48 CEST Tobias Imported from Hamamatsu datasheet.