Subdetector specification:  
Serial: 2004021749
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B05
Break-through voltage: 407 V
Voltage for Gain 100 (T=+25°C): 381.4 V
Dark current: 16.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 244
Position in Box: 12
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 21. Aug 2019
Sent for analysis after irradiation: 15. Oct 2019
Return for assembly: none
   
Irradiation:  
Date: 09. Oct 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 12. Oct 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 381.2936616 V     T = -25 °C: 345.4280398 V
Voltage for Gain 150: T = +20 °C: 389.0914639 V     T = -25 °C: 352.8571501 V
Voltage for Gain 200: T = +20 °C: 393.4307721 V     T = -25 °C: 357.033079 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.524458943 V-1     T = -25 °C: 4.76545932 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.90152978 V-1     T = -25 °C: 9.498399784 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.61636874 V-1     T = -25 °C: 14.99393094 V-1
Break-through voltage: T = +20 °C: 405.7397378 V     T = -25 °C: 372.1521432 V
   
Notes:


Version history

Time Author Change comment
10. Jun 2022 12:16:19 CEST oafedulidis Assigned to capsule by script
03. May 2021 15:18:37 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:19:40 CET jreher Updated box and position via API.
11. Aug 2020 17:42:52 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:31:28 CEST jreher Updated box and position via API.
16. Jan 2020 12:06:17 CET jreher Updated date sent for analysis after screening via API.
16. Jan 2020 12:04:27 CET jreher Updated annealing info via API.
16. Jan 2020 12:01:37 CET jreher Updated irradiation info via API.
16. Jan 2020 11:58:45 CET jreher Updated arrival for irradiation via API.
16. Jan 2020 11:57:44 CET jreher Updated arrival for irradiation via API.
27. Nov 2019 20:12:06 CET jreher Updated APD location via API.
25. Nov 2019 17:29:38 CET jreher Updated box and position via API.
22. Oct 2019 16:35:05 CEST spankonin Updated APD batch assignment via API.
22. Oct 2019 16:16:10 CEST spankonin Updated APD location via API.
23. Jun 2016 11:52:44 CEST Tobias Imported from Hamamatsu datasheet.