Show Hamamatsu Avalanche Photo Diode 2003021693 - Archived data from Fri, 05. February 2021 11:20:46 CET
This is all the information about APD 2003021693. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 2003021693 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | G06 |
Break-through voltage: | 405 V |
Voltage for Gain 100 (T=+25°C): | 377 V |
Dark current: | 6.7 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 252 |
Position in Box: | 25 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | 21. Aug 2019 |
Sent for analysis after irradiation: | 15. Oct 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 09. Oct 2019 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 12. Oct 2019 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 377.8899092 V T = -25 °C: 342.7886335 V |
Voltage for Gain 150: | T = +20 °C: 385.7968475 V T = -25 °C: 350.2032231 V |
Voltage for Gain 200: | T = +20 °C: 390.2104155 V T = -25 °C: 354.3837736 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.59130898 V-1 T = -25 °C: 4.961925842 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.970200568 V-1 T = -25 °C: 9.113108036 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 13.80982864 V-1 T = -25 °C: 16.06838326 V-1 |
Break-through voltage: | T = +20 °C: 404.9338913 V T = -25 °C: 369.2528491 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
29. Mar 2022 12:36:33 CEST | oafedulidis | Assigned to capsule by script |
03. May 2021 15:20:57 CEST | oafedulidis | Updated box and position via API. |
21. Apr 2021 14:52:56 CEST | oafedulidis | Updated box and position via API. |
05. Feb 2021 11:20:46 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:42:48 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:32:55 CEST | jreher | Updated box and position via API. |
16. Jan 2020 12:06:15 CET | jreher | Updated date sent for analysis after screening via API. |
16. Jan 2020 12:04:25 CET | jreher | Updated annealing info via API. |
16. Jan 2020 12:01:35 CET | jreher | Updated irradiation info via API. |
16. Jan 2020 11:58:43 CET | jreher | Updated arrival for irradiation via API. |
16. Jan 2020 11:57:42 CET | jreher | Updated arrival for irradiation via API. |
27. Nov 2019 20:13:28 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:30:04 CET | jreher | Updated box and position via API. |
22. Oct 2019 16:34:30 CEST | spankonin | Updated APD batch assignment via API. |
22. Oct 2019 16:15:26 CEST | spankonin | Updated APD location via API. |
23. Jun 2016 11:52:42 CEST | Tobias | Imported from Hamamatsu datasheet. |