RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2002021591 - Archived data from Wed, 07. October 2020 15:44:19 CEST


This is all the information about APD 2002021591. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2002021591
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: In transit to Mainz
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E07
Break-through voltage: 407 V
Voltage for Gain 100 (T=+25°C): 378.8 V
Dark current: 12.2 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 248
Position in Box: 49
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 378.854152 V     T = -25 °C: 343.4468997 V
Voltage for Gain 150: T = +20 °C: 386.6868571 V     T = -25 °C: 350.7682314 V
Voltage for Gain 200: T = +20 °C: 391.08016 V     T = -25 °C: 354.8889596 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.622542924 V-1     T = -25 °C: 4.742000893 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.126659457 V-1     T = -25 °C: 9.697712951 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.09084864 V-1     T = -25 °C: 15.26494775 V-1
Break-through voltage: T = +20 °C: 406.8415813 V     T = -25 °C: 370.2821089 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:20:16 CET jreher Updated box and position via API.
07. Oct 2020 15:44:19 CEST jreher Updated APD location via API.
11. Aug 2020 17:48:35 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:32:12 CEST jreher Updated box and position via API.
27. Nov 2019 20:12:54 CET jreher Updated APD location via API.
25. Nov 2019 17:29:55 CET jreher Updated box and position via API.
21. Nov 2019 16:54:05 CET spankonin Updated APD location via API.
21. Nov 2019 16:41:38 CET spankonin Updated APD batch assignment via API.
23. Jun 2016 11:51:43 CEST Tobias Imported from Hamamatsu datasheet.