RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1915021482 - Archived data from Mon, 17. August 2020 15:53:39 CEST


This is all the information about APD 1915021482. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1915021482
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B13
Break-through voltage: 413 V
Voltage for Gain 100 (T=+25°C): 386.2 V
Dark current: 6.4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 263
Position in Box: 46
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 386.2596766 V     T = -25 °C: 350.1936331 V
Voltage for Gain 150: T = +20 °C: 394.0793132 V     T = -25 °C: 357.6870642 V
Voltage for Gain 200: T = +20 °C: 398.4274549 V     T = -25 °C: 361.8872761 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.503288436 V-1     T = -25 °C: 4.774566907 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.928957293 V-1     T = -25 °C: 9.658713997 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.63609051 V-1     T = -25 °C: 15.11295901 V-1
Break-through voltage: T = +20 °C: 412.5254737 V     T = -25 °C: 376.7270233 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:22:14 CET jreher Updated box and position via API.
07. Oct 2020 12:27:29 CEST jreher Assigned to capsule by script
17. Aug 2020 15:53:39 CEST jreher Updated box and position via API.
11. Aug 2020 17:49:38 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:34:55 CEST jreher Updated box and position via API.
27. Nov 2019 20:15:13 CET jreher Updated APD location via API.
25. Nov 2019 17:30:39 CET jreher Updated box and position via API.
25. Nov 2019 17:17:52 CET spankonin Updated APD batch assignment via API.
23. Jun 2016 11:51:40 CEST Tobias Imported from Hamamatsu datasheet.