RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1915021427 - Archived data from Tue, 11. August 2020 17:49:49 CEST


This is all the information about APD 1915021427. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1915021427
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 0718006745/1915021427
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: red
   
Manufacturer information:  
Wafer position: G07
Break-through voltage: 407 V
Voltage for Gain 100 (T=+25°C): 378.7 V
Dark current: 15 nA
   
Screening Logistics:  
Available: No
Storage Box: 271
Position in Box: 1
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 379.456139 V     T = -25 °C: 344.3783134 V
Voltage for Gain 150: T = +20 °C: 387.2572706 V     T = -25 °C: 351.7304124 V
Voltage for Gain 200: T = +20 °C: 391.5984513 V     T = -25 °C: 355.8502598 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.508921891 V-1     T = -25 °C: 4.858669406 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.91297321 V-1     T = -25 °C: 9.897878192 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.69606548 V-1     T = -25 °C: 15.85993206 V-1
Break-through voltage: T = +20 °C: 406.7466032 V     T = -25 °C: 370.9276948 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:23:13 CET jreher Updated box and position via API.
11. Aug 2020 17:49:49 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:36:21 CEST jreher Updated box and position via API.
31. Mar 2020 08:52:37 CEST jreher Assigned to capsule by script
13. Feb 2020 14:21:51 CET jreher Updated box and position via API.
27. Nov 2019 20:16:16 CET jreher Updated APD location via API.
25. Nov 2019 17:30:51 CET jreher Updated box and position via API.
25. Nov 2019 17:15:50 CET spankonin Updated APD batch assignment via API.
23. Jun 2016 11:50:02 CEST Tobias Imported from Hamamatsu datasheet.