RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1914021335 - Archived data from Tue, 06. October 2020 16:52:33 CEST


This is all the information about APD 1914021335. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1914021335
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F07
Break-through voltage: 409 V
Voltage for Gain 100 (T=+25°C): 380.6 V
Dark current: 9.4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 255
Position in Box: 21
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 380.8344088 V     T = -25 °C: 345.3774486 V
Voltage for Gain 150: T = +20 °C: 388.6749177 V     T = -25 °C: 352.7453683 V
Voltage for Gain 200: T = +20 °C: 393.0174186 V     T = -25 °C: 356.8654827 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.650984957 V-1     T = -25 °C: 4.790455443 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.284273773 V-1     T = -25 °C: 9.745992724 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.49832911 V-1     T = -25 °C: 15.48502327 V-1
Break-through voltage: T = +20 °C: 408.3626288 V     T = -25 °C: 372.0065293 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:21:07 CET jreher Updated box and position via API.
29. Jan 2021 10:27:07 CET jreher Assigned to capsule by script
06. Oct 2020 16:52:33 CEST jreher Updated box and position via API.
11. Aug 2020 17:49:00 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:33:23 CEST jreher Updated box and position via API.
27. Nov 2019 20:14:00 CET jreher Updated APD location via API.
25. Nov 2019 17:30:17 CET jreher Updated box and position via API.
21. Nov 2019 16:56:18 CET spankonin Updated APD location via API.
21. Nov 2019 16:35:50 CET spankonin Updated APD batch assignment via API.
23. Jun 2016 11:50:00 CEST Tobias Imported from Hamamatsu datasheet.