RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1914021329 - Archived data from Tue, 11. August 2020 17:48:58 CEST


This is all the information about APD 1914021329. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1914021329
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: H07
Break-through voltage: 409 V
Voltage for Gain 100 (T=+25°C): 380.4 V
Dark current: 11.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 255
Position in Box: 16
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 381.5664406 V     T = -25 °C: 345.8763075 V
Voltage for Gain 150: T = +20 °C: 389.4220147 V     T = -25 °C: 353.2654058 V
Voltage for Gain 200: T = +20 °C: 393.7738157 V     T = -25 °C: 357.4138311 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.396457441 V-1     T = -25 °C: 4.961273982 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.572298145 V-1     T = -25 °C: 9.192366124 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.88953369 V-1     T = -25 °C: 16.34594383 V-1
Break-through voltage: T = +20 °C: 408.6267627 V     T = -25 °C: 372.139384 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:21:06 CET jreher Updated box and position via API.
07. Oct 2020 12:09:37 CEST jreher Assigned to capsule by script
17. Aug 2020 15:53:20 CEST jreher Updated box and position via API.
11. Aug 2020 17:48:58 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:33:23 CEST jreher Updated box and position via API.
27. Nov 2019 20:14:00 CET jreher Updated APD location via API.
25. Nov 2019 17:30:17 CET jreher Updated box and position via API.
21. Nov 2019 16:56:18 CET spankonin Updated APD location via API.
21. Nov 2019 16:35:49 CET spankonin Updated APD batch assignment via API.
23. Jun 2016 11:49:59 CEST Tobias Imported from Hamamatsu datasheet.