RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1913021255 - Archived data from Tue, 11. August 2020 17:49:51 CEST


This is all the information about APD 1913021255. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1913021255
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2311025095/1913021255
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: red
   
Manufacturer information:  
Wafer position: F05
Break-through voltage: 405 V
Voltage for Gain 100 (T=+25°C): 376.7 V
Dark current: 13.7 nA
   
Screening Logistics:  
Available: No
Storage Box: 271
Position in Box: 11
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 377.4879454 V     T = -25 °C: 342.4481594 V
Voltage for Gain 150: T = +20 °C: 385.3268915 V     T = -25 °C: 349.7700545 V
Voltage for Gain 200: T = +20 °C: 389.686938 V     T = -25 °C: 353.8911836 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.4678146 V-1     T = -25 °C: 4.793559473 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.660672093 V-1     T = -25 °C: 9.716332871 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.03018778 V-1     T = -25 °C: 15.4367244 V-1
Break-through voltage: T = +20 °C: 405.0146743 V     T = -25 °C: 369.0751638 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:23:14 CET jreher Updated box and position via API.
11. Aug 2020 17:49:51 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:36:22 CEST jreher Updated box and position via API.
03. Apr 2020 10:08:44 CEST jreher Assigned to capsule by script
13. Feb 2020 14:24:06 CET jreher Updated box and position via API.
27. Nov 2019 20:16:17 CET jreher Updated APD location via API.
25. Nov 2019 17:30:52 CET jreher Updated box and position via API.
25. Nov 2019 17:15:50 CET spankonin Updated APD batch assignment via API.
23. Jun 2016 11:49:58 CEST Tobias Imported from Hamamatsu datasheet.