RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1913021249 - Archived data from Mon, 17. August 2020 15:51:10 CEST


This is all the information about APD 1913021249. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1913021249
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E10
Break-through voltage: 410 V
Voltage for Gain 100 (T=+25°C): 381.5 V
Dark current: 8.3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 271
Position in Box: 45
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 382.1988723 V     T = -25 °C: 346.6308915 V
Voltage for Gain 150: T = +20 °C: 390.0067057 V     T = -25 °C: 354.0347672 V
Voltage for Gain 200: T = +20 °C: 394.3440648 V     T = -25 °C: 358.1978096 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.566857851 V-1     T = -25 °C: 4.697296436 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.077978329 V-1     T = -25 °C: 9.451951169 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.12573604 V-1     T = -25 °C: 14.97460569 V-1
Break-through voltage: T = +20 °C: 409.2686379 V     T = -25 °C: 373.2123204 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:23:18 CET jreher Updated box and position via API.
07. Oct 2020 16:40:31 CEST jreher Assigned to capsule by script
17. Aug 2020 15:51:10 CEST jreher Updated box and position via API.
11. Aug 2020 17:49:58 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:36:25 CEST jreher Updated box and position via API.
20. Feb 2020 13:35:30 CET jreher Updated box and position via API.
27. Nov 2019 20:16:19 CET jreher Updated APD location via API.
25. Nov 2019 17:30:54 CET jreher Updated box and position via API.
25. Nov 2019 17:14:11 CET spankonin Updated APD batch assignment via API.
23. Jun 2016 11:49:57 CEST Tobias Imported from Hamamatsu datasheet.